1. Disassembly
Safety: Use appropriate tools (such as wrenches and sockets) during disassembly to avoid forceful impact that could damage the threads or strip the zinc coating.
Cleaning and Inspection: After disassembly, thoroughly clean the threaded holes of rust and impurities to ensure smooth installation of the new bolts.
2. Selection of New Bolts
Matching Specifications: The diameter, length, and strength grade (e.g., 8.8, 10.9) of the new bolts must match the original bolts to avoid connection failure due to size or strength mismatches.
The hot-dip galvanizing layer thickness should be >= 54μm (for standard bolts) or 80μm (for highly corrosive environments), in compliance with GB/T 5267.1-2012.
Preferably, bolts that have been centrifugally treated after plating should be used to minimize thread interference caused by zinc buildup. 3. Anti-corrosion Treatment
Recoating: If the zinc coating of new bolts is damaged during installation, recoat with zinc-rich primer or epoxy resin to enhance corrosion protection.
Avoid Mixing: Hot-dip galvanized bolts should not be mixed with cold-dip galvanized bolts, as differences in process may cause galvanic corrosion.
4. Installation and Inspection
Torque Control: Apply torque according to GB/T 3098.1-2010 to avoid overtightening (which may crack the zinc coating) or undertightening (which may result in insufficient preload).
Thread Fit: During installation, check the thread fit of the nut and bolt to ensure there is no jamming (a go/no-go gauge can be used for spot checks).
Record and Archive: After replacement, record the bolt specifications, installation date, and torque parameters for easy tracking during future maintenance.